12,000 BTU 21.5 SEER DC Inverter Ductless Mini Split Heat Pump

Ductless A/C Heat Pump Systems 18,000 BTU 21 SEER DC Inverter Ductless Mini Split Heat Pump

12,000 BTU 21.5 SEER DC Inverter Ductless Mini Split Heat Pump 12,000 BTU 21.5 SEER DC Inverter Ductless Mini Split Heat Pump 12,000 BTU 21.5 SEER DC Inverter Ductless Mini Split Heat Pump 12,000 BTU 21.5 SEER DC Inverter Ductless Mini Split Heat Pump 12,000 BTU 21.5 SEER DC Inverter Ductless Mini Split Heat Pump 12,000 BTU 21.5 SEER DC Inverter Ductless Mini Split Heat Pump 12,000 BTU 21.5 SEER DC Inverter Ductless Mini Split Heat Pump Features

Model: DA1221-H2

Energy Star 21.5 SEER
DC Inverter Compressor
Golden fin anti-corrosive condenser
HEPA filter included
LED dispay
Exceptionally Quiet Operation
Low ambient operation
Refrigerant leak detection
Smart Air Flow
2 direction air vane technology
Built-in electronic diagnostic
Outdoor pan heater
Self cleaning
Louver position memory and much more... 


 



  • Product Description
  • Specifications
  • Downloads
  • Where to buy
    • Golden fin anti-corrosive condenser: the golden hydrophilic condenser improves the heating efficiency by accelerating the defrosting process, the unique anti-corrosive golden coating on the condenser also aids in withstanding the effects of salty air, rain and other corrosive elements by allowing contaminated water on the coil to run off more quickly reducing the corrosive effect to the coil, heat exchange performance is much longer lasting
    • Low ambient operation: a special built-in low ambient kit can be used in temperatures as low as 5°F for cooling operation, useful for users who need to maintain cooling during winter
    • Refrigerant leak detection: with this new technology the system will alarm when a refrigerant leak is detected
    • Follow me feature: by pressing the ‘follow me’ button and keeping the remote close to you, you tell the air conditioner to set the temperature from wherever the remote happens to be, this counteracts the tendency for the air conditioner to stop cooling or heating because the air around the unit has reached its set temperature (switches off after period of inactivity to preserve battery life)
    • HEPA filter included (1): a HEPA filter is a type of mechanical air filter; it works by forcing air through a fine mesh that traps harmful particles such as pollen, pet dander, dust mites, and tobacco smoke
    • Two direction air vane technology: in cooling mode the air vane opens counter clockwise to direct the air horizontally, allowing for an even cooling effect, in heating mode the air vane opens clockwise directing the air downwards, this time for an even heating effect
    • Built-in electronic diagnostic: monitoring some abnormal operations or parts failures, microcomputer of the air conditioner will switch off and protect the system automatically; meanwhile, the error or protection code will be displayed on the indoor unit
    • Outdoor pan heater: a heating belt is fitted on the base plate of the outdoor unit to avoid accumulation of rain, snow or water on the base plate
    • Dual washable filters: a good air conditioner should not only take care of the temperature in your home but also the quality of the air you breathe, the system aids in removing most of the pollen dust, smoke and other microscopic airborne particles that by latest thinking contribute to respiratory problems like asthma and hay fever
    • Self cleaning: by pressing clean on the remote control automatically cleans the evaporator to aid in reducing build-up of bacteria and keep the air fresh
    • Sleep mode: in sleep mode, the unit automatically decreases the heating or increases the cooling by 1° per hour for the first 2 hours of use, then holds the temperature steady for 5 hours before ceasing operation
    • Low noise airflow system: without decreasing the airflow volume and capacity output, large diameter cross flow fan can bring down the indoor unit noise level by lowering the fan speed
    • Anti cold draft: if the unit is turn on in heat mode when the ambient temperature is low it will warm up prior to fan operation to prevent cold air in heating mode to make people feel more comfortable
    • Louver position memory: the set louver position is stored in memory by the microcomputer, and the louver returns to the stored position when the next operation is performed
    • Turbo mode: this function enables the unit to reach the preset temperature in the shortest time

TECHNICIAN BULLETS:

  • Line sets MUST be a minimum of 10 Feet in order to function properly. If the line set is less than 10 Feet it may result an irreversible system malfunction.
  • When there is a determined need to adjust the refrigerant charge, it must be figured by weight in accordance with the unit’s specifications.   Measuring refrigerant amount by use of pressure technique is improper procedure!
  • Rubber mounts are included with all our condensers and MUST be placed on the bottom of the feet during installation to absorb the vibration. This is a critical step as without these rubber mounts, future damages may incur within the unit due to consistent vibration over time.
  • If condensers are installed and secured on a mounting bracket, be sure not to over tighten the mounting bolts around the unit’s feet.  By over tightening the bolts, the rubber mounts will be constricted and defeat the purpose to absorb vibration. Refer to bullet 3.

Power supply (V/hz)

208-230/60

Cooling

12,000

Heating

12,000

SEER

21.5

HSPF

9.8

EER 

13

Dehumidification (Pts/hr)

2.75

Current Cooling (Amp)

4.05

Heating (Amp)

4.72

Power Input Cooling (Watt)

923

Heating (Watt)

1085

Indoor Air Circulation:
L / M / H (CFM)

147/212/306

Indoor Noise level dB(A): L / M / H

25/30/36.5

Outdoor Fan Speed (RPM)

--/--/---

Outdoor Noise Level dB(A)

~ 57.5

Indoor Fan Speeds (RMP)

1080/850/650

Connection Method

Flare

Max Pipe Length (Ft)

82

Max Elevation (Ft)

33

Pipe Size

1/4" / 1.2"

Service Port Connection

1/2"

Indoor Dimensions
W x D x H (In.)

31.57 X 7.44 X 11.69 

Indoor Package Dimensions
W x D x H (In.)

34.45 X 11.22 X 14.76

Indoor Net Weight (lbs.)

18.1

Indoor Gross Weight (lbs.)

22

Outdoor Dimensions
W x D x H (In.)

31.5 X 13.11 X 21.81

Outdoor Package Dimensions
W x D x H (In.)

36.22 X 15.35 X 24.21

Outdoor Net Weight (lbs.)

81.60

Outdoor Gross Weight (lbs.)

88.20

Refrigerant

R410A


TECHNICIAN BULLETS:

  • Line sets MUST be a minimum of 10 Feet in order to function properly. If the line set is less than 10 Feet it may result an irreversible system malfunction.
  • When there is a determined need to adjust the refrigerant charge, it must be figured by weight in accordance with the unit’s specifications.   Measuring refrigerant amount by use of pressure technique is improper procedure!
  • Rubber mounts are included with all our condensers and MUST be placed on the bottom of the feet during installation to absorb the vibration. This is a critical step as without these rubber mounts, future damages may incur within the unit due to consistent vibration over time.
  • If condensers are installed and secured on a mounting bracket, be sure not to over tighten the mounting bolts around the unit’s feet.  By over tightening the bolts, the rubber mounts will be constricted and defeat the purpose to absorb vibration. Refer to bullet 3.